Maxim MX7705 Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
MX7705
16-Bit, Low-Power, 2-Channel,
Sigma-Delta ADC
______________________________________________________________________________________ 27
POLL DRDY
OUTPUT
POWER-ON RESET
INITIALIZE
μ
C/
μ
P SERIAL
PORT
WRITE TO THE SETUP REGISTER. SET
SELF-CALIBRATION MODE, GAIN TO 0,
UNIPOLAR MODE, UNBUFFERED MODE.
BEGIN SELF-CALIBRATION/CONVERSION
BY CLEARING FSYNC.
(0x44)
WRITE TO THE COMMUNICATIONS
REGISTER. SELECT CHANNEL 1 AND SET
NEXT OPERATION AS A WRITE TO THE
SETUP REGISTER.
(0x10)
WRITE TO THE CLOCK REGISTER. ENABLE
EXTERNAL OSCILLATOR. SELECT
OUTPUT UPDATE RATE OF 60Hz.
(0xA5)
WRITE TO THE COMMUNICATIONS
REGISTER. SELECT CHANNEL 1 AND SET
NEXT OPERATION AS A WRITE TO THE
CLOCK REGISTER.
(0x20)
WRITE TO THE COMMUNICATIONS
REGISTER. SET NEXT OPERATION AS A
READ FROM THE DATA REGISTER.
(0x38)
READ THE DATA REGISTER
(16 BITS)
WRITE TO COMMUNICATIONS REGISTER.
SET NEXT OPERATION AS A READ FROM
THE COMMUNICATIONS REGISTER.
(0x08)
READ THE COMMUNICATIONS REGISTER
(8 BITS)
HARDWARE POLLING SOFTWARE POLLING
0 (DATA
READY)
0 (DATA
READY)
1 (DATA
NOT
READY)
1 (DATA NOT
READY)
POLL DRDY
BIT
Figure 11. Sample Flow Diagram for Data Conversion
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 33

Comentarios a estos manuales

Sin comentarios